Approved Vendor

Flow Transmitter with Sight

Manufacturer part: 9687K24

Send flow rate data using these transmitters while also being able to visually confirm liquid is flowing. They measure flow by counting how many times the turbine turns as the liquid moves through it. To prevent clogging the turbine and other damage, use them only with clean, low-viscosity liquids. These transmitters, also known as transducers, convert the flow measurement to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs), to monitor flow or control equipment. Mount them directly inline with your system. They measure accurately in any mounting orientation.These transmitters are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.Digital Pulse Output—Transmitters with a digital pulse output send flow data using spikes of voltage that match the input voltage of the transmitter. The higher the flow, the more pulses they send.

✓ Normalized specifications✓ Supplier verified
Availability
In stock
Lead time
Contact supplier
Sold by
Approved Vendor

Technical data

Specifications

Normalized product attributes for faster comparison and sourcing.

ECCN
EAR99
Accuracy
-15% to 15%
Includes
Flow Sight
Measures
Flow Rate
Flow Range
8 gpm to 60 gpm
Connects To
Pipe
For Use With
Liquids
Body Material
Brass
Certification
CE Marked, UL Listed, UL Recognized Component
Seal Material
Fluoroelastomer
Output Voltage
4.5V DC to 24V DC
UL File Number
E45168
Calibrated With
Water
Pulse Frequency
15 Hz to 225 Hz
RoHS Compliance
RoHS 3 (2015/863/EU) Compliant
Warning Message
Chemical compatibility must be determined by the customer based on the conditions in which the product is being used, including the presence of other chemicals, temperature, and consistency.
Wire Connection
Wire Leads
DFARS Compliance
Specialty Metals COTS-Exempt
Fitting Material
Brass
Pipe Connections
1 NPT Female
REACH Compliance
REACH (EC 1907/2006) (06/27/2024, 241 SVHC) Compliant
USMCA Qualifying
No
Wire Lead Length
24"
Country of Origin
United States
End-to-End Length
3 ,15/16,"
Maximum Viscosity
200 SSU
Mounting Location
Inline
Mounting Position
Any Angle
Schedule B Number
903289.6060
Temperature Range
33° F to 212° F
Circuit Protection
Reverse Polarity, Short Circuit
Fitting Connection
Threaded
Output Signal Type
Digital
Digital Output Type
Pulse
Flow Indicator Type
Sight
Input Voltage Range
4.5V DC to 24V DC
Field Recalibratable
No
Flow Measurement Type
Turbine
Wetted Parts Material
316 Stainless Steel, Polysulfone, PPS, Viton® Fluoroelastomer
Flow Measurement Scale
Gallons per Minute
Maximum Output Current
70 mA
Total Number of Outputs
1
Maximum Pressure @ Temperature
200 psi @ 70° F
Electrical Connection Permanence
Hardwire

Supplier coverage

Compare available offers

Review pricing, availability, and fulfillment details from verified distributors.

SupplierSupplier SKUPriceStockLead timeType
Approved Vendor9687K24Request priceContact supplierContact supplierAuthorized · US distributor

Prices and availability are provided by suppliers and may change.